| Firetrol® FTA200 alarm panels are designed to meet the NFPA 20 specifications requiring a remote alarm panel when the pump house or pump room is not constantly attended. The alarm panel must be installed in a location that is under supervision at all times.
Firetrol alarm panels are listed by Underwriters Laboratories, Inc., in accordance with UL508, Standard for Industrial Controls, certified by CSA, Standard for Industrial Control Equipment (cUL), approved by the New York City Bureau of Electrical Control and Board of Standards and Appeals and Factory Mutual. They are designed to meet or exceed the requirements of the approving authorities listed above as well as NFPA 20, Installation of Centrifugal Fire Pumps. There are four basic models of alarm panels: FTA200 Type A - Designed for use with electric motor driven fire pump controllers, they provide audible and visible indication for the supervisory voltage pump operating, pump phase failure, and pump phase reversal conditions. FTA200 Type B - Designed for use with electric motor driven fire pump controllers, they provide visible only indication for the supervisory voltage and audible and visible indication of pump operating, pump phase failure, and pump phase reversal conditions. FTA200 Type F - Designed for use with diesel engine driven fire pump controllers, they provide visible only indication for the supervisory voltage, and audible and visable indication of engine trouble, engine running, and main switch mis-set conditions. FTA200 Type G - Designed for use with diesel engine driven fire pump controllers, they provide visible only indication for the supervisory voltage and audible and visable indication of engine trouble, engine running, main switch mis-set conditions, and pump room trouble conditions. Firetrol® FTA200 low suction pressure alarm and shutdown panels are intended for use where a local authority mandates pump shutdown in the event of low suction pressure. Firetrol low suction pressure alarm and shutdown panels have been approved by Factory Mutual. WARNING: Because NFPA 20 specifically prohibits the installation of any device in the suction piping which will restrict starting or stopping of the fire pump (See NFPA 20 (2007), Paragraph 5.14.9.1), ASCO Power Technologies, LP assumes no liability when Type D or E Shutdown Panels are used in conjunction with fire pump control equipment. There are two basic models of low suction pressure alarm and shutdown panels: FTA200 Type D - Resets automatically when suction pressure is restored. FTA200 Type E - Must be reset manually when suction pressure is restored. |
|||||||||||||||||||||||
| Alarm Panels | |||||||||||||||||||||||
| Low Suction Shutdown Panels |
|||||||||||||||||||||||
|
|
|||||||||||||||||||||||
|
|||||||||||||||||||||||